Product Features
Fifteen filtered functions
Product Technical Spec.
Overall Length:
1.541 inches
Overall Height:
1.020 inches
Overall Width:
0.625 inches
Unthreaded Mounting Hole Diameter:
0.122 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
1.312 inches
Operating Tempurature Range:
-55.0/+85.0 degrees celsius
End Application:
Tactical air operations module an/tyq-2 (v) 1
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
Source Impedance Rating Per Function:
50.0 ohms 5th radio interference
Source Impedance Rating Per Function:
50.0 ohms 6th radio interference
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference
Load Impedance Per Function:
50.0 ohms 1st radio interference
Load Impedance Per Function:
50.0 ohms 3rd radio interference
Load Impedance Per Function:
50.0 ohms 2nd radio interference
Load Impedance Per Function:
50.0 ohms 6th radio interference
Load Impedance Per Function:
50.0 ohms 4th radio interference
Load Impedance Per Function:
50.0 ohms 5th radio interference
Operating Current Rating Per Function In Amps:
7.5 1st radio interference
Operating Current Rating Per Function In Amps:
7.5 3rd radio interference
Operating Current Rating Per Function In Amps:
7.5 4th radio interference
Operating Current Rating Per Function In Amps:
7.5 5th radio interference
Operating Current Rating Per Function In Amps:
7.5 6th radio interference
Operating Current Rating Per Function In Amps:
7.5 2nd radio interference
Maximum Voltage Drop Per Function:
1.0 volts dc 1st radio interference
Maximum Voltage Drop Per Function:
1.0 volts dc 2nd radio interference
Maximum Voltage Drop Per Function:
1.0 volts dc 3rd radio interference
Maximum Voltage Drop Per Function:
1.0 volts dc 4th radio interference
Maximum Voltage Drop Per Function:
1.0 volts dc 5th radio interference
Maximum Voltage Drop Per Function:
1.0 volts dc 6th radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 4th radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 3rd radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 5th radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 6th radio interference
Full Load Insertion Loss Frequencies In Megahertz:
25.0 and 50.0 and 100.0 and 300.0 and 500.0 and 1000.0
Full Load Minimum Insertion Loss At Specificationified Frequency In Decibels:
10.0 and 15.0 and 20.0 and 40.0 and 50.0 and 55.0
Inclosure Type:
Hermetically sealed
Mounting Facility Type And Quantity:
2 unthreaded hole
Functional Terminal Type And Quantity:
15 friction w/grounding strap and pin input-output
Operating Voltage Rating And Type Per Function:
100.0 volts dc 1st radio interference 1st function
Operating Voltage Rating And Type Per Function:
100.0 volts dc 2nd radio interference 2nd function
Operating Voltage Rating And Type Per Function:
100.0 volts dc 3rd radio interference 3rd function
Operating Voltage Rating And Type Per Function:
100.0 volts dc 4th radio interference 4th function
Operating Voltage Rating And Type Per Function:
100.0 volts dc 5th radio interference 5th function
Operating Voltage Rating And Type Per Function:
100.0 volts dc 6th radio interference 6th function
Maximum Dielectric Withstanding Dc Voltage:
250.0 volts at sea level
Body Surface Treatment:
Tin
Precious Material And Location:
Contact surfaces gold
Style Designator:
Filter connector
Item Name:
Ac Ripple Filter
Cross Referenced Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC